TECHNICAL DATA
| MODEL | TYPHOON CLASSIC 15E 420b |
| AIR DELIVERY FAD | 250 lit/min |
| MAX WORKING PRESSURE | 420 bar |
| STAGES | 3 |
| CYLINDERS | 3 |
| CYLINDER ARRANGEMENT | W |
| 1ST STAGE CYLINDER DIAMETER | 80mm |
| 2ND STAGE CYLINDER DIAMETER | 36mm |
| 3RD STAGE CYLINDER DIAMETER | 14mm |
| PISTON STROKE | 60mm |
| SPEED ROTATION | 1100 rpm |
| 1ST STAGE PRESSURE | 5,2 – 5,5 bar |
| 2ND STAGE PRESSURE | 38 – 43 bar |
| TRANSMISSION | V Belt |
| MOTOR POWER | 5,5 kW/ 400V/50Hz
6,3 kW/ 440V/60Hz (Class F, IP 55) |
| OIL CAPACITY | 1.6 lit synthetic compressor oil |
| AIR OUTLET TEMPERATURE | 5 – 8 Co above ambient temperature |
| MAX PERMISSIBLE AMBIENT TEMPERATURE | +50 to +450 C |
| COOLING AIR FLOW MIN REQUIRED APPROXIMATELY | 1980m3/ hr |
| MAX INCLINATION OF COMPRESSOR | 150 |
| DIMENSIONS (L x W x H) | 71 X 125 X 83 cm |
| WEIGHT | 216-232 Kg |
| FILLING TIME OF CYL 10LT @ 420BAR | 16,80 min ± 5% |
STANDARD EQUIPMENT |
| Micronic Air Intake Filter. |
| Condensate Separator after 2nd Stage. |
| Large Stainless Steel Intercoolers & aftercooler at all stages.
o 2nd stage intercooler extra (420b version) o 3th stage aftercooler extra (420b version) |
| Improved heatsink at 2nd stage valve/cylinder head (420b version) |
| Improved heatsink at final (3rd) stage valve head & cylinder head (420b version) |
| Large fan (500mm diam.) for optimum cooling of cylinders, intercoolers & aftercoolers, making the compressor capable for continuous operation. |
| Combined BA Filter D110Χ495 420bar max. including Coalescing Pre-filter (0,5mg/m3 oil residual) and 1 x (Active Carbon / Molecular Sieve cartridge) Ø65Χ260 cartridge, with the supply of absolutely clean air exceeding by far the requirements of EN 12021:2014. |
| Pressure maintaining valve & non-return valve allowing for safe, efficient & extended filtration. |
| Direct on line starting system. |
| Start/Stop switch. |
| Motor thermal overload protection. |
| 24V secondary voltage providing safety during routine operation. |
| Emergency Stop button. |
| Automatic start & stop at the desirable pressure.
o 500bar pressure switch (420bar version) |
| Automatic Condensate Drains with manual backups.
o 400bar solenoid valve @ final stage (420bar version) |
| Condensate collecting tank with level indication |
| ¼’’ BSPP high pressure outlet. |
| Safety Valves in all stages. |
| Inter stage (1st, 2nd) manometers and Final Stage 400 bar manometer. |
| Built-In Vibration Pads. |
| Automatic belt tensioning system. |
| Hourmeter |
| Final Stage Condensate Separator (420 bar version) |
| Low oil level Sensor / Alarm & Shut down (420bar version). |
| High temperature alarm & shutdown error via bimetal switch. |
OPTIONAL EQUIPMENT |
| Voltage failure and phase rotation safety device. |
| Extra Combined BA Filter D110x495 including Coalescing Pre-filter (0,5mg/m3 oil residual) and 1 x (Active Carbon / Molecular Sieve cartridge) D65Χ260 cartridges, with the supply of absolutely clean air exceeding by far the requirements of EN 12021:2014. |
| Star Delta Starting System |
| Oil Pump Lubrication System c/w low oil pressure switch Alarm / Shut Down, oil cooler, oil filter & flow regulator. |
| Humidity Control
Filter state control system, PARAMINA HUMIDITY CONTROL, a device with main target to control humidity of high pressure air via: 1. A Central monitoring unit with display, led indicators and menu navigation buttons. 2. A Humidity Sensor incorporated in stainless steel chamber. PARAMINA HUMIDITY CONTROL provides complete information regarding filters’ state (Filter OK – Filter Critical – Change Filter) in terms of humidity, giving the possibility at the same time, to check the reliability of all devices/systems that remove humidity from the air. The use of this device is intended only for this purpose and not for any other use (e.g. cannot replace laboratory humidity measurement devices). Power Supply: 230VAC 50-60Hz or 24VAC 50-60Hz or 24VDC Operating Temperature: +5oC to +45Oc Max. Operating pressure: 420bar Process connection: G1/4 thread § Every 2 years the sensor must be checked and recalibrated or else replaced. In networks with bad air quality, every year. § The humidity sensor is recommended to be installed in between final filter and pressure maintaining valve, vertically as per arrow indication. Power Supply: 230VAC 50-60Hz or 24VAC 50-60Hz or 24VDC Max working Pressure: 420bar |
| Automatic start system |
| Remote Start / Stop. |
| Special Voltage/Frequency: 230V/50Hz – 230V/60Hz – 3x 230V/60Hz. |
| Two (2) wheels on the one side of compressor for easy transport. |
Recommended Spares
- PARAMINA HPA Oil n.:112755000 (1,6ltr per replacement – replacement every 1.000 working hours and once per year irrespective of the working hours).
- Coalescing pre-filter cartridge n.:306049631 (1 pc per replacement-replacement every 200 working hours and once a year irrespective of the working hours).
Air intake cartridge p.n.:109460302 (1 pc per replacement-replacement every 200 working hours and once a year irrespective of the working hours).
- AC/MS Cartridge n.:137000080 (1 pc per replacement-replacement every 35 working hours @20 oC ambient temperature and every six months irrespective of the working hours).
- Oil Pump Filter n.108000682 – when equipped with compressor (1pc per replacement – replacement every 1.000 working hours and once per year irrespective of the working hrs).